What is the outside diameter of 72 inch pipe?
72 inch (NPS 72, DN 1800) pipe has an outside diameter of 1829 mm (72 in). The OD stays the same for every schedule; a heavier schedule only reduces the inside diameter.
NPS 72 · DN 1800
72 inch nominal pipe has a fixed outside diameter of 1829 mm (72 in). B36.10M and B36.19M list 13 wall thicknesses for this size, from 12.7 mm to 31.75 mm.
Metric
| Schedule | Wall mm | ID mm | Mass kg/m | Water-filled kg/m | Flow area mm² |
|---|---|---|---|---|---|
| Listed wall (no schedule number) | 12.70 | 1803.60 | 568.87 | 3123.75 | 2,554,879 |
| Listed wall (no schedule number) | 14.27 | 1800.46 | 638.64 | 3184.63 | 2,545,991 |
| Listed wall (no schedule number) | 15.88 | 1797.24 | 710.06 | 3246.95 | 2,536,892 |
| Listed wall (no schedule number) | 17.48 | 1794.04 | 780.92 | 3308.79 | 2,527,866 |
| Listed wall (no schedule number) | 19.05 | 1790.90 | 850.32 | 3369.35 | 2,519,025 |
| Listed wall (no schedule number) | 20.62 | 1787.76 | 919.60 | 3429.80 | 2,510,200 |
| Listed wall (no schedule number) | 22.23 | 1784.54 | 990.52 | 3491.69 | 2,501,166 |
| Listed wall (no schedule number) | 23.83 | 1781.34 | 1060.87 | 3553.07 | 2,492,204 |
| Listed wall (no schedule number) | 25.40 | 1778.20 | 1129.78 | 3613.21 | 2,483,425 |
| Listed wall (no schedule number) | 26.97 | 1775.06 | 1198.57 | 3673.23 | 2,474,662 |
| Listed wall (no schedule number) | 28.58 | 1771.84 | 1268.98 | 3734.67 | 2,465,692 |
| Listed wall (no schedule number) | 30.18 | 1768.64 | 1338.83 | 3795.62 | 2,456,794 |
| Listed wall (no schedule number) | 31.75 | 1765.50 | 1407.25 | 3855.33 | 2,448,078 |
Imperial
| Schedule | Wall in | ID in | Weight lb/ft | Flow area in² |
|---|---|---|---|---|
| Listed wall (no schedule number) | 0.500 | 71.000 | 382.17 | 3959.192 |
| Listed wall (no schedule number) | 0.562 | 70.876 | 429.18 | 3945.375 |
| Listed wall (no schedule number) | 0.625 | 70.750 | 476.87 | 3931.360 |
| Listed wall (no schedule number) | 0.688 | 70.624 | 524.48 | 3917.369 |
| Listed wall (no schedule number) | 0.750 | 70.500 | 571.25 | 3903.625 |
| Listed wall (no schedule number) | 0.812 | 70.376 | 617.93 | 3889.905 |
| Listed wall (no schedule number) | 0.875 | 70.250 | 665.29 | 3875.989 |
| Listed wall (no schedule number) | 0.938 | 70.124 | 712.55 | 3862.098 |
| Listed wall (no schedule number) | 1.000 | 70.000 | 758.99 | 3848.451 |
| Listed wall (no schedule number) | 1.062 | 69.876 | 805.34 | 3834.829 |
| Listed wall (no schedule number) | 1.125 | 69.750 | 852.36 | 3821.011 |
| Listed wall (no schedule number) | 1.188 | 69.624 | 899.29 | 3807.219 |
| Listed wall (no schedule number) | 1.250 | 69.500 | 945.40 | 3793.669 |
Walls shared by more than one designation are merged into one row (for example STD / Sch 40 / 40S). Inch walls are converted from the millimetre values and rounded to three decimals.
Questions
72 inch (NPS 72, DN 1800) pipe has an outside diameter of 1829 mm (72 in). The OD stays the same for every schedule; a heavier schedule only reduces the inside diameter.
Plain-end carbon steel mass per metre is 0.0246615 x (OD - t) x t with OD and wall t in mm (ASME B36.10M). For imperial units use 10.69 x (OD - t) x t with inches, giving lb/ft. Stainless steel is roughly 2% heavier because of its higher density.
Nearby sizes
NPS 60 · DN 1500 · OD 1524 mm · 17 walls
Open sizeNPS 64 · DN 1600 · OD 1626 mm · 17 walls
Open sizeNPS 68 · DN 1700 · OD 1727 mm · 14 walls
Open sizeNPS 76 · DN 1900 · OD 1930 mm · 13 walls
Open sizeNPS 80 · DN 2000 · OD 2032 mm · 12 walls