Worked example
A 6 m floor beam with a 10 kN/m uniform load
Inputs
- Simply supported, span L = 6 m, w = 10 kN/m
- Steel E = 200 GPa, Ix = 8356 cm⁴, Zx = 557 cm³
- Deflection limit L/300 = 20 mm
Working
- δ = 5wL⁴ / 384EI = 5 x 10 x 6000⁴ / (384 x 200000 x 8.356 x 10⁷) = 10.1 mm
- M = wL² / 8 = 10 x 6² / 8 = 45 kN·m
- σ = M / Z = 45 x 10⁶ / 557 x 10³ = 80.8 MPa
Result: 10.1 mm deflection (L/594) passes the 20 mm limit. Bending stress is 80.8 MPa before load factors and buckling checks.