Skip to content
EnggToolsMechanical engineering tools

Free tool · no sign-in

ISO fits and tolerances calculator.

Choose a nominal size and a hole and shaft class, or tap a preferred fit, to get upper and lower limits, size limits and the resulting clearance or interference.

Results
Fit typeClearance fit
Class25 H7/g6
Maximum clearance41 µm
Minimum clearance7 µm
Limits for 25 mm. Deviations in µm, sizes in mm.
FeatureUpper dev.Lower dev.Max sizeMin sizeIT µm
Hole H7+21025.02125.00021
Shaft g6-7-2024.99324.98013

How to use it

Step by step, with a worked example.

  1. Enter the nominal size in millimetres, the same basic size for the hole and the shaft.
  2. Choose the hole class (letter and IT grade) and the shaft class, or tap a preferred fit such as H7/g6.
  3. Read the upper and lower limits for each part, in micrometres and as finished sizes in millimetres.
  4. Check the fit type and the maximum and minimum clearance. A negative clearance is interference.

Worked example

A 25 mm sliding fit, H7/g6

Inputs

  • Nominal size 25 mm (range over 18 up to 30 mm)
  • Hole H7: IT7 = 21 µm, lower deviation 0
  • Shaft g6: IT6 = 13 µm, upper deviation -7 µm

Working

  • Hole: 25.000 to 25.021 mm
  • Shaft: 24.980 to 24.993 mm
  • Max clearance = 25.021 - 24.980 = 0.041 mm; min clearance = 25.000 - 24.993 = 0.007 mm

Result: A clearance fit with 7 to 41 µm of play: the shaft always slides in, with accurate location.

Preferred fits

Common fits at 25 mm.

Clearance is positive, interference negative, in µm.
FitTypeMax clearanceMin clearanceTypical use
H11/d11 · Loose runningClearance+325+65Wide tolerances, agricultural and construction pins.
H9/d9 · Free runningClearance+169+65Large temperature variation, high speed or heavy journal pressure.
H8/f7 · Close runningClearance+74+20Accurate location on running shafts at moderate speed.
H7/g6 · SlidingClearance+41+7Parts that move and turn freely and locate accurately; spigots.
H7/h6 · Locational clearanceClearance+340Snug fit for stationary parts that can be assembled by hand.
H7/k6 · Locational transitionTransition+19-15Accurate location; compromise between clearance and interference.
H7/n6 · Locational transitionTransition+6-28More accurate location where greater interference is acceptable.
H7/p6 · Locational interferenceInterference-1-35Rigid alignment without special bore pressure; light press fit.
H7/s6 · Medium driveInterference-14-48Steel parts or shrink fits on light sections; tightest usable in cast iron.

Chart

H7 hole and common shaft deviations.

Upper / lower deviation in µm for each nominal size range (mm).
Size rangeH7g6h6k6n6p6s6
up to 3+10 / 0-2 / -80 / -6+6 / 0+10 / +4+12 / +6+20 / +14
3 to 6+12 / 0-4 / -120 / -8+9 / +1+16 / +8+20 / +12+27 / +19
6 to 10+15 / 0-5 / -140 / -9+10 / +1+19 / +10+24 / +15+32 / +23
10 to 18+18 / 0-6 / -170 / -11+12 / +1+23 / +12+29 / +18+39 / +28
18 to 30+21 / 0-7 / -200 / -13+15 / +2+28 / +15+35 / +22+48 / +35
30 to 50+25 / 0-9 / -250 / -16+18 / +2+33 / +17+42 / +26+59 / +43
50 to 80+30 / 0-10 / -290 / -19+21 / +2+39 / +20+51 / +32+72 / +53
80 to 120+35 / 0-12 / -340 / -22+25 / +3+45 / +23+59 / +37+93 / +71
120 to 180+40 / 0-14 / -390 / -25+28 / +3+52 / +27+68 / +43+125 / +100
180 to 250+46 / 0-15 / -440 / -29+33 / +4+60 / +31+79 / +50+151 / +122
250 to 315+52 / 0-17 / -490 / -32+36 / +4+66 / +34+88 / +56+202 / +170
315 to 400+57 / 0-18 / -540 / -36+40 / +4+73 / +37+98 / +62+226 / +190
400 to 500+63 / 0-20 / -600 / -40+45 / +5+80 / +40+108 / +68+272 / +232

r and s shafts change at intermediate sizes above 50 mm (for example 50-65 and 65-80); the calculator applies those sub-ranges automatically.

Questions

Frequently asked.

What does H7/g6 mean?

The capital letter and number describe the hole (H, grade IT7) and the lower-case pair the shaft (g, grade IT6). H holes have a lower deviation of zero, so the hole is never smaller than nominal. A g shaft is always slightly undersize, giving a precise sliding clearance fit.

What is the tolerance of a 25 mm H7 hole?

25 H7 is +0.000 / +0.021 mm, so the bore must be between 25.000 and 25.021 mm. The 21 µm band is the IT7 standard tolerance for sizes over 18 up to 30 mm.

Which fit should I use for a bearing or a press-fit pin?

Bearing seats depend on load direction and bearing size, so use the bearing maker's recommendation (often k5/k6 or m6 shafts for rotating inner rings). Dowel pins in steel commonly use H7/m6 or H7/p6; check assembly force with an interference-fit calculation.

What is the difference between hole-basis and shaft-basis fits?

Hole-basis systems keep the hole at H and change the shaft letter; they are preferred because reamers and plug gauges are standard. Shaft-basis systems keep the shaft at h and change the hole letter, which suits long drawn bar used without machining.

Coverage. Sizes up to 500 mm; holes D to S in IT6 to IT11 (K, M, N to IT8; P, R, S to IT7) and shafts d to s in IT5 to IT11, following ISO 286-1 and ISO 286-2. Confirm critical limits against the standard and your drawing.

Keep going